Frequency estimation precision in Doppler optical coherence tomography using the Cramer-Rao lower bound
Chicago
Abstract
Doppler optical coherence tomography (DOCT) is a technique for simultaneous cross-sectional imaging of tissue structure and blood flow. We derive the fundamental uncertainty limits on frequency estimation precision in DOCT using the Cramer-Rao lower bound in the case of additive (e.g., thermal, shot) noise. Experimental results from a mirror and a scattering phantom are used to verify the theoretical limits. Our results demonstrate that the stochastic nature of frequency noise influences the precision of flow imaging, and that the noise model must be selected judiciously in order to estimate the frequency precision.
Additional Information
© 2005 Optical Society of America Received 3 December 2004; revised 29 December 2004; accepted 5 January 2005 This study was supported by National Institutes of Health grant EY-13015. We gratefully acknowledge fruitful discussions with Jeff Krolik at Duke University, Bill Walker at the University of Virginia, and Jason Connor at Carnegie Mellon University. S. Yazdanfar is currently with the Massachusetts Institute of Technology, Cambridge, MA. C. Yang is currently with the California Institute of Technology, Pasadena, CA.Attached Files
Published - YAZoe05.pdf
Files
YAZoe05.pdf
Files
(242.2 kB)
Name | Size | Download all |
---|---|---|
md5:0c793985229b1ab9f55d28d5ecf1515a
|
242.2 kB | Preview Download |
Additional details
- Eprint ID
- 3313
- Resolver ID
- CaltechAUTHORS:YAZoe05
- NIH
- EY-13015
- Created
-
2006-05-30Created from EPrint's datestamp field
- Updated
-
2020-03-09Created from EPrint's last_modified field