- Creators
- Tan, F. Dong
- Vollin, Jeff L.
- Ćuk, Slobodan
Chicago
Abstract
Accuracy of a direct measurement of core-loss power is severely limited in many applications by the extra phase shift between the measured voltage and current. An analysis of the error is for the first time performed, which not only unfolds the hidden physical nature behind it, but also reveals a simple and effective method to control the sensitivity and hence the error. This method can also be used to satisfy a prescribed tolerance. Extensive measurements on a TDK PC40 core yield results which support the analysis.
Additional Information
© Copyright 1995 IEEE. Reprinted with permission. Manuscript received March 15, 1993; revised November 11, 1994.Files