Published February 1, 1954 | public
Journal Article Open

Link Coupling for Nuclear Magnetic Resonance

An error occurred while generating the citation.

Abstract

In an attempt to use proton magnetic resonance for regulation of magnetic fields of 10 kilogauss or more, it has been found that the conventional probe sample holder used by other investigators (1) gave inadequate, if any, resonance lines above 40 mc/sec. In such arrangements, the oscillator tank coil is at the end of a coaxial probe. The weaker lines at higher frequencies are attributed to the fact that the distributed inductance of the coaxial line becomes important as frequency is increased. To overcome this difficulty, we have employed a link-type coupling arrangement.

Additional Information

Copyright © 1954 American Institute of Physics. (Received September 14, 1953)