Welcome to the new version of CaltechAUTHORS. Login is currently restricted to library staff. If you notice any issues, please email coda@library.caltech.edu
Published June 18, 2021 | Submitted + Supplemental Material + Published
Journal Article Open

Interferometric Constraints on Spacelike Coherent Rotational Fluctuations

Abstract

Precision measurements are reported of the cross-spectrum of rotationally induced differential position displacements in a pair of colocated 39 m long, high-power Michelson interferometers. One arm of each interferometer is bent 90° near its midpoint to obtain sensitivity to rotations about an axis normal to the plane of the instrument. The instrument achieves quantum-limited sensing of spatially correlated signals in a broad frequency band extending beyond the 3.9-MHz inverse light travel time of the apparatus. For stationary signals with bandwidth Δf > 10  kHz, the sensitivity to rotation-induced strain h of classical or exotic origin surpasses CSD_(δh) < t_P/2, where t_P = 5.39 × 10 ⁻⁴⁴  s is the Planck time. This measurement is used to constrain a semiclassical model of nonlocally coherent rotational degrees of freedom of spacetime, which have been conjectured to emerge in holographic quantum geometry but are not present in a classical metric.

Additional Information

© 2021 American Physical Society. Received 15 December 2020; accepted 21 April 2021; published 14 June 2021. This work was supported by Fermi National Accelerator Laboratory (Fermilab), a U.S. Department of Energy, Office of Science, HEP User Facility, managed by Fermi Research Alliance, LLC, acting under Contract No. DE-AC02-07CH11359. We are grateful for support from the John Templeton Foundation, the University of Chicago-Fermilab Strategic Collaborative Initiatives program, and the Fermilab Laboratory Directed Research and Development program. J. R. was partially supported by the Visiting Scholars Award Program of the Universities Research Association (Grant No. 18-S-20). O. K. was partially supported by the Basic Science Research Program (Grant No. NRF-2016R1D1A1B03934333) of the National Research Foundation of Korea funded by the Ministry of Education. The Holometer team gratefully acknowledges the extensive support and contributions of Gregory L. Brown, Andrea Bryant, Erin Glynn, Raymond H. Lewis, Arlo Marquez-Grap, Jeronimo Martinez, Matthew Quinn, James E. Ranson, Eleanor Rath, George Ressinger, and Michael Shemanske in the construction and operation of the apparatus. We also thank Rana Adhikari and Hartmut Grote for insightful comments during the data analysis and interpretation.

Attached Files

Published - PhysRevLett.126.241301.pdf

Submitted - 2012.06939.pdf

Supplemental Material - Supplemental_Material.pdf

Files

PhysRevLett.126.241301.pdf
Files (2.1 MB)
Name Size Download all
md5:fbe2d5159b5165f305a189030ca2c26d
531.2 kB Preview Download
md5:17a8e99318364fade65b04aa206650fd
1.1 MB Preview Download
md5:8d299bf055c19947a8ba82f449b3e4a5
459.4 kB Preview Download

Additional details

Created:
August 20, 2023
Modified:
October 23, 2023