Welcome to the new version of CaltechAUTHORS. Login is currently restricted to library staff. If you notice any issues, please email coda@library.caltech.edu
Published May 2019 | Accepted Version + Supplemental Material
Journal Article Open

High-throughput, label-free, single-cell photoacoustic microscopy of intratumoral metabolic heterogeneity

Abstract

Intratumoral heterogeneity, which is manifested in almost all of the hallmarks of cancer, including the significantly altered metabolic profiles of cancer cells, represents a challenge to effective cancer therapy. High-throughput measurements of the metabolism of individual cancer cells would allow direct visualization and quantification of intratumoral metabolic heterogeneity, yet the throughputs of current measurement techniques are limited to about 120 cells per hour. Here, we show that single-cell photoacoustic microscopy can reach throughputs of approximately 12,000 cells per hour by trapping single cells with blood in an oxygen-diffusion-limited high-density microwell array and by using photoacoustic imaging to measure the haemoglobin oxygen change (that is, the oxygen consumption rate) in the microwells. We demonstrate the capability of this label-free technique by performing high-throughput single-cell oxygen-consumption-rate measurements of cultured cells and by imaging intratumoral metabolic heterogeneity in specimens from patients with breast cancer. High-throughput single-cell photoacoustic microscopy of oxygen consumption rates should enable the faster characterization of intratumoral metabolic heterogeneity.

Additional Information

© 2019 Springer Nature Publishing AG. Received 06 March 2018; Accepted 26 February 2019; Published 01 April 2019. Data availability: The authors declare that all data supporting the results in this study are available within the paper and its Supplementary information. The source data for the figures in this study are available in https://doi.org/10.6084/m9.figshare.7744004. The authors appreciate the help received from J. Yao in the initial phase of the project and J. Liang in the data analysis while they were former members of our laboratory. We also thank J. Ballard for his close reading of the manuscript. This work was sponsored by National Science Foundation (grant nos 1255930 and 1255921) and National Institutes of Health (grant nos DP1 EB016986 (NIH Director's Pioneer Award) and R01 CA186567 (NIH Director's Transformative Research Award)). Author Contributions: P.H., J.Z. and L.V.W. conceived and designed the study. P.H. and T.I. developed the photoacoustic imaging system. S.X. fabricated the high-density microwell array. R.Z. cultured the cells. R.L.A. provided the excised breast cancer and normal tissues. P.H. and T.I. performed the experiments. P.H. and T.I. analysed the data. L.V.W. supervised the study. All authors wrote the manuscript. Competing interests: L.V.W. has a financial interest in Microphotoacoustics, Inc.; CalPACT, LLC and Union Photoacoustic Technologies, Ltd. These companies did not support this work.

Attached Files

Accepted Version - nihms-1028028.pdf

Supplemental Material - 41551_2019_376_MOESM1_ESM.pdf

Supplemental Material - 41551_2019_376_MOESM2_ESM.pdf

Files

41551_2019_376_MOESM2_ESM.pdf
Files (3.0 MB)
Name Size Download all
md5:8b4ed4f1fbf37b13c0f86c5a5fe202e8
117.2 kB Preview Download
md5:dcc619177a070f54f7aaf4cb65140783
1.2 MB Preview Download
md5:dba7362905ed0e786ca5f901173c6554
1.7 MB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 20, 2023