Welcome to the new version of CaltechAUTHORS. Login is currently restricted to library staff. If you notice any issues, please email coda@library.caltech.edu
Published January 25, 2019 | Supplemental Material + Published
Journal Article Open

Digital Loop-Mediated Isothermal Amplification on a Commercial Membrane

Abstract

In this work, we report digital loop-mediated isothermal amplification (LAMP) or reverse-transcription LAMP (RT-LAMP) on a commercial membrane, without the need for complex chip fabrication or use of specialized equipment. Due to the pore size distribution, the theoretical error for digital LAMP on these membranes was analyzed, using a combination of Random Distribution Model and Multi-volume Theory. A facile peel-off process was developed for effective droplets formation on the commercial track-etched polycarbonate (PCTE) membrane. Each pore functions as an individual nanoreactor for single DNA amplification. Absolute quantification of bacteria genomic DNA was realized with a dynamic range from 11 to 1.1  105 copies/µL. One-step digital RT-LAMP was also successfully performed on the membrane for the quantification of MS2 virus in wastewater. With the introduction of new probes, the positive pores can be easily distinguished from negative ones with 100 times difference in fluorescence intensities. Finally, the cost of a disposable membrane is less than $0.1/piece, which, to the best of our knowledge, is the most inexpensive way to perform digital LAMP. The membrane system offers opportunities for point-of-care users or common laboratories to perform digital quantification, single cell analysis, or other bioassays in an inexpensive, flexible and simplified way.

Additional Information

© 2019 American Chemical Society. ACS AuthorChoice - This is an open access article published under a Creative Commons Attribution (CC-BY) License, which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited. Received: November 15, 2018; Accepted: January 3, 2019; Published: January 3, 2019. The authors acknowledge the financial support provided by the Bill and Melinda Gates Foundation (Grant No. OPP1111252). Author Contributions: All authors have given approval to the final version of the manuscript. The authors declare no competing financial interest.

Attached Files

Published - acssensors.8b01419.pdf

Supplemental Material - se8b01419_si_001.pdf

Supplemental Material - se8b01419_si_002.avi

Files

se8b01419_si_001.pdf
Files (9.0 MB)
Name Size Download all
md5:3b0aac55e52072d8bec3babb7de6ce59
1.0 MB Preview Download
md5:1f6572e13f3b2143b7be2e271c41d992
5.6 MB Download
md5:4116c3584968e260f10a87464a111ba8
2.4 MB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 19, 2023