Published January 1957
| public
Journal Article
A proportional counter system with small wall effect
- Creators
- Drever, R. W. P.
- Moljk, A.
- Curran, S. C.
Chicago
Abstract
The wall effects interfering with low energy measurements with proportional counters using gaseous sources are discussed, and a new type of counter in which they are considerably reduced is described. A layer of gas surrounding the sensitive volume is turned into a separate detector by a multiwire counting system which prevents escaping electrons or X-rays being registered. Applications to a new measurement of the L/K-capture ration of ^(71)Ge, and to low level counting, are described.
Additional Information
© 1957 Elsevier B.V. Received 22 August 1956.Additional details
- Eprint ID
- 63189
- Resolver ID
- CaltechAUTHORS:20151223-131335052
- Created
-
2015-12-23Created from EPrint's datestamp field
- Updated
-