Published November 5, 2015
| Submitted
Report
Open
Use of Fine Unheated Wires for Heat Transfer Measurements in the Shock Tube
- Creators
- Christiansen, Walter H.
Abstract
This report describes the application of fine cold wires for heat transfer measurements in the shock tube. The use of the calorimetric property of the wire results in a heat transfer instrument with an output of .25 mv/oC and a response lag of less than 1 µsec. The gage construction, calibration, and response characteristics are discussed. Some preliminary results are also presented.
Additional Information
Army Ordnance Contract No. DA-04-495-Ord-1960.Attached Files
Submitted - No._55.pdf
Files
No._55.pdf
Files
(8.0 MB)
Name | Size | Download all |
---|---|---|
md5:92b1454afe0546069f16414064d63629
|
8.0 MB | Preview Download |
Additional details
- Eprint ID
- 61852
- Resolver ID
- CaltechAUTHORS:20151104-151224999
- DA-04-495-Ord-1960
- U.S. Army Office of Ordnance
- Created
-
2015-11-05Created from EPrint's datestamp field
- Updated
-
2019-10-03Created from EPrint's last_modified field
- Caltech groups
- Hypersonic Research Project, GALCIT
- Series Name
- Hypersonic Research Project Memorandum
- Series Volume or Issue Number