Welcome to the new version of CaltechAUTHORS. Login is currently restricted to library staff. If you notice any issues, please email coda@library.caltech.edu
Published July 21, 2015 | Submitted
Report Open

Force and Cavitation Tests Westinghouse Hydrobomb

Abstract

This report covers Water Tunnel tests of a 2" diameter scale model of the Westinghouse Hydrobomb. The results apply only to underwater performance under steady state conditions. No tests were made to determine damping characteristics. The tests reported herein were authorized by a letter dated January 29, 1944, from Dr. E. H. Colpitts, Chief of Section 6.1, National Defense Research Committee.

Additional Information

Office of Scientific Research & Development National Defense Research Committee Division Six-Section 6.1. Section No 6.1-Sr207-2234 Laboratory No ND-40.

Attached Files

Submitted - ND-40.pdf

Files

ND-40.pdf
Files (5.0 MB)
Name Size Download all
md5:6b9d25dd03246042d2c43dbdb7649891
5.0 MB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 23, 2023