Abstract
Precision light monitoring is important for keeping excellent energy resolution promised by LSO/LYSO crystals in severe radiation environment. In this paper, we report an investigation on the wavelength choice for monitoring LYSO crystal based calorimeters. Gamma-ray induced absorption and light output loss were measured for 20 cm long crystals from five different vendors. Monitoring sensitivity and divergence between crystals from different vendors were investigated. The pros and cons of two monitoring approaches using emission and excitation light and their practical implementation for a LYSO/W Shashlik test beam matrix are discussed.
Additional Information
© 2015 The Authors. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. This work was supported in part by the US Department of Energy Grant DE-FG03-92-ER40701.Attached Files