Welcome to the new version of CaltechAUTHORS. Login is currently restricted to library staff. If you notice any issues, please email coda@library.caltech.edu
Published December 7, 2014 | Submitted
Journal Article Open

Hydraulic external pre-isolator system for LIGO

Abstract

The hydraulic external pre-isolator (HEPI) is the first six degrees of freedom active seismic isolation system implemented at the Laser Interferometer Gravitational Wave Observatory (LIGO). Implementation was first completed at the LIGO Livingston Observatory (LLO) prior to LIGOʼs fifth science run, successfully cutting down the disturbance seen by LLOʼs suspended optics in the two most prominent seismic disturbance bands, the microseism (0.1–0.3 Hz) and the anthropogenic (1–3 Hz) bands, by a factor of a few to tens. The improvement in seismic isolation contributed directly to LLOʼs much improved duty cycle of 66.7% and LIGOʼs triple coincident duty cycle of 53%. We report the design, control scheme, and isolation performance of HEPI at LLO in this paper. Aided by this success, funding for incorporating HEPI into the LIGO Hanford Observatory was approved and installation is currently underway.

Additional Information

© 2014 IOP Publishing Ltd. Received 30 April 2014, revised 14 August 2014. Accepted for publication 26 August 2014. Published 13 November 2014. The authors acknowledge financial support from the National Science Foundation through grants PHY-0071316, 0107417, 0140297, 0304924, and 9801158, as well as the Louisiana Board of Regents contract LEQSF(2000–03)-RD-A-06.

Attached Files

Submitted - 1309.5685v1.pdf

Files

1309.5685v1.pdf
Files (7.6 MB)
Name Size Download all
md5:a6d610ff0127e8fb7a8af974c615cadb
7.6 MB Preview Download

Additional details

Created:
August 20, 2023
Modified:
October 19, 2023