Welcome to the new version of CaltechAUTHORS. Login is currently restricted to library staff. If you notice any issues, please email coda@library.caltech.edu
Published January 28, 2014 | Supplemental Material + Accepted Version
Journal Article Open

Oxidatively Responsive Chain Extension to Entangle Engineered Protein Hydrogels

Abstract

Engineering artificial protein hydrogels for medical applications requires precise control over their mechanical properties, including stiffness, toughness, extensibility, and stability in the physiological environment. Here we demonstrate topological entanglement as an effective strategy to robustly increase the mechanical tunability of a transient hydrogel network based on coiled-coil interactions. Chain extension and entanglement are achieved by coupling the cysteine residues near the N- and C-termini, and the resulting chain distribution is found to agree with the Jacobson–Stockmayer theory. By exploiting the reversible nature of the disulfide bonds, the entanglement effect can be switched on and off by redox stimuli. With the presence of entanglements, hydrogels exhibit a 7.2-fold enhanced creep resistance and a suppressed erosion rate by a factor of 5.8, making the gels more mechanically stable in a physiologically relevant open system. While hardly affecting material stiffness (only resulting in a 1.5-fold increase in the plateau modulus), the entanglements remarkably lead to hydrogels with a toughness of 65 000 J m^(–3) and extensibility to approximately 3000% engineering strain, which enables the preparation of tough yet soft tissue simulants. This improvement in mechanical properties resembles that from double-network hydrogels but is achieved with the use of a single associating network and topological entanglement. Therefore, redox-triggered chain entanglement offers an effective approach for constructing mechanically enhanced and responsive injectable hydrogels.

Additional Information

© 2014 American Chemical Society. Received: August 11, 2013; Revised: December 30, 2013; Published: January 16, 2014. This research was supported by the U.S. Army Research Office through the Institute of Soldier Nanotechnologies under Contract W911NF-07-D-0004. The authors thank Biophysical Instrumentation Facility at MIT (NSF-0070319) for the use of the CD spectrophotometer. M.J.G. was supported by an NIH Interdepartmental Biotechnology Training Program (2-T32-GM08334), and S.L. was supported by a Summer Undergraduate Research Fellowship (SURF) from Caltech Student-Faculty Programs.

Attached Files

Accepted Version - nihms557518.pdf

Supplemental Material - ma401684w_si_001.pdf

Files

nihms557518.pdf
Files (1.5 MB)
Name Size Download all
md5:fcdeb23b808706b62724a7eb8ff899db
850.8 kB Preview Download
md5:a5f0bca2e0e3248435708d52d2e24661
681.9 kB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 26, 2023