Published March 1966
| Published
Journal Article
Open
Diffusivity Measurements of Human Methemoglobin
- Creators
- Keller, K. H.
- Friedlander, S. K.
Chicago
Abstract
Experimental measurements of the diffusion coefficient of human methemoglobin were made at 25°C with a modified Stokes diaphragm diffusion cell. A Millipore filter was used in place of the ordinary fritted disc to facilitate rapid achievement of steady state in the diaphragm. Methemoglobin concentrations varied from approximately 5 g/100 ml to 30 g/100 ml. The diffusion coefficient in this range decreased from 7.5 x 10^(-7) cm^2/sec to 1.6 x 10^(-7) cm^2/sec.