CaltechTHESIS
  A Caltech Library Service

Thermal noise in the initial LIGO interferometers

Citation

Gillespie, Aaron D. (1995) Thermal noise in the initial LIGO interferometers. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/yn3r-ny82. https://resolver.caltech.edu/CaltechETD:etd-10032007-142542

Abstract

NOTE: Text or symbols not renderable in plain ASCII are indicated by [...]. Abstract is included in .pdf document. Gravitational wave detectors capable of detecting broadband gravitational wave bursts with a strain amplitude sensitivity near [...] at frequencies around 100 Hz are currently under construction by the LIGO (Laser Interferometer Gravitational-wave Observatory) and VIRGO groups. One challenge facing these groups is how to detect the motion of the center of an inertial mass to a precision of [...] m when the mass consists of atoms each of which individually moves much more than that due to thermal energy. The uncertainty in the interferometer's measurement due to these thermal motions is called thermal noise. This thesis describes the thermal noise of the initial LIGO detectors. The thermal noise was analyzed by modelling the normal modes of the test mass suspension system as harmonic oscillators with dissipation and applying the fluctuation dissipation theorem. The dissipation of all modes which contribute significant thermal noise to the interferometer was measured and from these measurements the total thermal noise was estimated. The frequency dependence of the dissipation of the pendulum mode was characterized from measurements of the violin modes. A steel music wire suspension system was found to meet the goals of the initial LIGO detectors. A mathematical technique was developed which relates the energy in each vibrational mode to the motion of the mirror surface measured by the interferometer. Modes with acoustic wavelengths greater than the laser beam spot size can contribute significant thermal noise to the interferometer measurements. The dissipation of the test masses of LIGO's 40-m interferometer at Caltech was investigated, and a technique for suspending and controlling the test masses which lowered the dissipation and met the thermal noise goals of the initial LIGO detector was developed. New test masses were installed in the 40-m interferometer resulting in improved noise performance. The implications of thermal noise to detecting gravitational waves from inspiralling compact binaries was investigated. An optimal pendulum length for detecting these signals was found. It was shown that the narrow band thermally excited violin resonances could be efficiently filtered from the broadband gravitational wave signal.

Item Type:Thesis (Dissertation (Ph.D.))
Degree Grantor:California Institute of Technology
Major Option:Physics
Thesis Availability:Public (worldwide access)
Thesis Committee:
  • Raab, Frederick J. (chair)
Defense Date:26 April 1995
Record Number:CaltechETD:etd-10032007-142542
Persistent URL:https://resolver.caltech.edu/CaltechETD:etd-10032007-142542
DOI:10.7907/yn3r-ny82
Default Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:3887
Collection:CaltechTHESIS
Deposited By: Imported from ETD-db
Deposited On:18 Oct 2007
Last Modified:16 Apr 2021 23:23

Thesis Files

[img]
Preview
PDF (Gillespie_ad_1995.pdf) - Final Version
See Usage Policy.

5MB

Repository Staff Only: item control page