CaltechTHESIS
  A Caltech Library Service

I. Numerical Solution of the Superfluid Shock Jump Conditions. II. Experimental Investigation of the Liquid Helium II-Vapor Interface

Citation

Moody, Douglas Marion, Jr. (1983) I. Numerical Solution of the Superfluid Shock Jump Conditions. II. Experimental Investigation of the Liquid Helium II-Vapor Interface. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/387M-V435. https://resolver.caltech.edu/CaltechETD:etd-08312006-081008

Abstract

Numerical Solution of the Superfluid Shock Jump Conditions

The four fundamental conservation equations of superfluid mechanics may be integrated across a one-dimensional discontinuity (shock wave) propagating into undisturbed helium II to yield a set of four algebraic equations (jump conditions) which, when supplemented by thermodynamic state information, establish the equilibrium flow state behind the shock wave for a given wave speed and undisturbed flow state ahead of the shock. These jump conditions have been solved numerically for 19 points on the helium II p-T diagram with upstream Mach number as the independent parameter. Representative results of the calculations are presented for pressure shocks, temperature raising shocks, and temperature lowering shock. The results are compared to previous analytical approximate solutions to test the validity of those approximation. They are also compared to experimental data for shock waves in helium II as a means of testing the correctness of the full, nonlinear two-fluid equations.

Experimental Investigation of the Liquid Helium II-Vapor Interface

An apparatus was designed and constructed to measure the linear reflection and transmission coefficients for weak second sound shocks impinging upon the liquid-vapor interface of helium II. The measured reflection coefficients reproduce the work of previous authors, giving values which are roughly 20% higher than those predicted by thermodynamic equilibrium theory. The transmitted pressure wave speed was measured, and was found to be sonic within the limits of experimental precision. Therefore strength could not be deduced from time of flight measurements. Direct amplitude measurements of this weak wave were prevented by the film which coats the sensors in the vapor. For these reasons, the attempted transmission coefficient measurements were unsuccessful.

Item Type:Thesis (Dissertation (Ph.D.))
Subject Keywords:Applied Physics
Degree Grantor:California Institute of Technology
Division:Engineering and Applied Science
Major Option:Applied Physics
Thesis Availability:Public (worldwide access)
Research Advisor(s):
  • Goodstein, David L.
Thesis Committee:
  • Johnson, William Lewis (chair)
  • Goddard, William A., III
  • Goodstein, David L.
  • Liepmann, Hans Wolfgang
  • Sturtevant, Bradford
Defense Date:6 May 1983
Record Number:CaltechETD:etd-08312006-081008
Persistent URL:https://resolver.caltech.edu/CaltechETD:etd-08312006-081008
DOI:10.7907/387M-V435
Default Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:3292
Collection:CaltechTHESIS
Deposited By: Imported from ETD-db
Deposited On:14 Sep 2006
Last Modified:21 Dec 2019 02:22

Thesis Files

[img]
Preview
PDF - Final Version
See Usage Policy.

4MB

Repository Staff Only: item control page