Published September 15, 1992 | public
Journal Article Open

Linewidth and frequency jitter measurement of an erbium-doped fiber ring laser by using a loss-compensated, delayed self-heterodyne interferometer

Abstract

The single-mode line width of erbium-doped, single-frequency, fiber ring laser has been measured by using a newly developed loss-compensated delayed self-heterodyne interferometer that has a resolution of less than 600 Hz. The natural linewidth is determined to have an upper bound of less than 2 kHz. In addition, frequency jitter was found to be dominant over the natural linewidth, yielding an effective linewidth of approximately 4 kHz.

Additional Information

© 1992 Optical Society of America. Received May 15, 1992. The authors thank the Northrop Corporation for their support of this research and Ortel Corporation for providing the fast photodiode.