Toward in vivo detection of hydrogen peroxide with ultrasound molecular imaging

Abstract

We present a new class of ultrasound molecular imaging agents that extend upon the design of micromotors that are designed to move through fluids by catalyzing hydrogen peroxide (H_2O_2) and propelling forward by escaping oxygen microbubbles. Micromotor converters require 62 mm of H_2O_2 to move – 1000-fold higher than is expected in vivo. Here, we aim to prove that ultrasound can detect the expelled microbubbles, to determine the minimum H_2O_2 concentration needed for microbubble detection, explore alternate designs to detect the H_2O_2 produced by activated neutrophils and perform preliminary in vivo testing. Oxygen microbubbles were detected by ultrasound at 2.5 mm H_2O_2. Best results were achieved with a 400–500 nm spherical design with alternating surface coatings of catalase and PSS over a silica core. The lowest detection limit of 10–100 μm was achieved when assays were done in plasma. Using this design, we detected the H2O2 produced by freshly isolated PMA-activated neutrophils allowing their distinction from naïve neutrophils. Finally, we were also able to show that direct injection of these nanospheres into an abscess in vivo enhanced ultrasound signal only when they contained catalase, and only when injected into an abscess, likely because of the elevated levels of H_2O_2 produced by inflammatory mediators.

Additional Information

© 2013 Elsevier Ltd. Received 7 May 2013, Accepted 26 June 2013, Available online 16 August 2013. T32-EB005970 provided salary support for EO; Beatriu de Pinoìs Fellowship from the Government of Catalonia provided support for J.O; W.G. is a HHMI International Student Research fellow; Study was supported by ICMIC P50 CA128346 and NSF CBET 0853375. We wish to thank Siemens Medical Solutions for providing the Sequoia 512 scanner as an equipment loan. We would also like to thank Allan Cortes, Ashley Pourazary, Christopher Barback and Jacqueline Corbeil for providing technical assistance and for helpful discussion.

Attached Files

Accepted Version - nihms502188.pdf

Supplemental Material - 1-s2.0-S0142961213007709-mmc1.pdf

Supplemental Material - 1-s2.0-S0142961213007709-mmc2.pdf

Supplemental Material - 1-s2.0-S0142961213007709-mmc3.pdf

Supplemental Material - 1-s2.0-S0142961213007709-mmc4.pdf

Supplemental Material - 1-s2.0-S0142961213007709-mmc5.pdf

Supplemental Material - 1-s2.0-S0142961213007709-mmc6.mp4

Files

1-s2.0-S0142961213007709-mmc5.pdf
Files (7.6 MB)
Name Size Download all
md5:b7a48cc689a963f85c4da08e0bc2dfec
81.2 kB Preview Download
md5:4f5b5d91a022de98192348165bd1dca1
262.2 kB Preview Download
md5:90871514ef2b990172d01667b3781778
210.8 kB Preview Download
md5:63966f03c273321a5cbff1d2baaca25e
947.6 kB Preview Download
md5:9b0fcb0f0db4adeac88745de53782304
277.8 kB Preview Download
md5:29063bac62c95431e9c8f7ffeb375ba4
2.8 MB Download
md5:564f5649b0c4c28ade00f5b806cbfdc6
3.1 MB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 18, 2023