Phase-Contrast OCT Imaging of Transverse Flows in the Mouse Retina and Choroid

Abstract

Purpose. To test the hypothesis that a novel phase-contrast optical coherence tomography (OCT) system can image retinal and choroidal vessels in the living mouse. Methods. A high-speed spectral domain optical coherence tomography (SDOCT) system, which measures the reflections for the entire depth of the retina at once with each axial scan (A-scan), was developed for mouse retinal imaging. Acquiring multiple A-scans over a transverse line across the mouse retina offers a two-dimensional cross-sectional image (B-scan); several neighboring B-scans can be assembled into a three-dimensional OCT image. To visualize mobility and transverse flow in retinal vessels, the statistical variance of phase for each location was calculated from multiple B-scans acquired successively for the same retinal cross-section. Such measures of phase variance offer a direct measure of motions over a large dynamic range of flow velocities. Results. Three-dimensional phase-contrast images of the live mouse retina were created using multiple two-dimensional cross-sectional image slices through the retina. For the data presented here, each cross-sectional phase-contrast slice resulted from five images of 100 or 200 transverse pixels, acquired over 25 ms or 50 ms, respectively. The approach offered clear identification of motion regions at different depths, including flow in the retinal microvasculature and in the choroidal vessels. Conclusions. Phase-contrast OCT enables three-dimensional visualization of retinal and choroidal vasculature in vivo.

Additional Information

© 2008 Association for Research in Vision and Ophthalmology. Submitted for publication December 18, 2007; revised February 17 and June 6, 2008; accepted September 15, 2008. Supported by That Man May See, the Hellman Foundation, the Lincy Foundation, Research to Prevent Blindness, and National Eye Institute Core Grant EY02162. The authors thank Carl Zeiss Meditec for generously providing technical and material assistance in the development of the imaging system.

Attached Files

Published - z7g01108005055.pdf

Files

z7g01108005055.pdf
Files (310.3 kB)
Name Size Download all
md5:8cfabab9b8fc89b1b22405ff3cf7e971
310.3 kB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 17, 2023