Published October 1991 | public
Journal Article

Optimal temperature of fixed-bed reactor for high temperature removal of hydrogen sulfide

Abstract

To find optimal temperature of the reaction between H_2S gas and ZnO-5 at% Fe_2O_3 sorbent, the effluent gas from a fixed-bed reactor was analyzed by gas chromatography. The experimental results showed that H_2S removal efficiency of sorbent was maximum at 650°C and EDX data were in accordance with this feature. XRD analysis exhibited intriguing phenomenon in that different mechanisms were observed at different temperatures. Chemisorption and chemical reaction was considered to be the main mechanism of H_2S removal at 600 C and 650°C, respectively. SEM photographs supported this interesting phenomenon, but unfortunately TGA and DTA results could not distinguish it. To investigate the effect of sorbent deactivation on the reaction rate, deactivating factor was considered.

Additional Information

© 1991 Springer. Received 23 July 1991, accepted 25 November 1991.