Water Tunnel Tests of the MK25 Torpedo with Expanding Exhaust Pipe
- Creators
- Knapp, Robert T.
- Doolittle, Harold L.
Abstract
This report covers tests made on the Mk 25 torpedo to determine the effect of gas discharged through a horizontal expanding exhaust pipe, being the second supplement to the report, Section No. 6.1-sr207-1275. This testing was requested by Dr. E. H. Colpitts , Chief of Section 6.1 , NDRC , in a letter dated May 4, 1944. As in the two former series of tests, the object was to determine the feasibility of discharging the turbine exhaust gases through the fin structure instead of through the propeller shafts. Several different lengths of exhaust pipe were tested; also runs were made for various values of velocity, submergence, and quantity of gas discharged. Photographs were taken to show the exhaust cavities under the different conditions.
Additional Information
Office of Scientific Research & Development National Defense Research Committee Division Six-Section 6.1. Section 6.1-Sr-207-1642.Attached Files
Submitted - ND-30.2.pdf
Files
Name | Size | Download all |
---|---|---|
md5:508de4dfed1748dabe625799b8439580
|
3.3 MB | Preview Download |
Additional details
- Eprint ID
- 58997
- Resolver ID
- CaltechAUTHORS:20150723-172422354
- Created
-
2015-07-24Created from EPrint's datestamp field
- Updated
-
2019-10-03Created from EPrint's last_modified field
- Caltech groups
- Hydrodynamics Laboratory