Published June 1, 2010 | Accepted Version + Supplemental Material
Journal Article Open

Nanoliter Multiplex PCR Arrays on a SlipChip

Abstract

The SlipChip platform was tested to perform highthroughput nanoliter multiplex PCR. The advantages of using the SlipChip platform for multiplex PCR include the ability to preload arrays of dry primers, instrument-free sample manipulation, small sample volume, and highthroughput capacity. The SlipChip was designed to preload one primer pair per reaction compartment and to screen up to 384 different primer pairs with less than 30 nanoliters of sample per reaction compartment. Both a 40-well and a 384-well design of the SlipChip were tested for multiplex PCR. In the geometries used here, the sample fluid was spontaneously compartmentalized into discrete volumes even before slipping of the two plates of the SlipChip, but slipping introduced additional capabilities that made devices more robust and versatile. The wells of this SlipChip were designed to overcome potential problems associated with thermal expansion. By using circular wells filled with oil and overlapping them with square wells filled with the aqueous PCR mixture, a droplet of aqueous PCR mixture was always surrounded by the lubricating fluid. In this design, during heating and thermal expansion, only oil was expelled from the compartment and leaking of the aqueous solution was prevented. Both 40-well and 384-well devices were found to be free from cross-contamination, and end point fluorescence detection provided reliable readout. Multiple samples could also be screened on the same SlipChip simultaneously. Multiplex PCR was validated on the 384-well SlipChip with 20 different primer pairs to identify 16 bacterial and fungal species commonly presented in blood infections. The SlipChip correctly identified five different bacterial or fungal species in separate experiments. In addition, the presence of the resistance gene mecA in methicillin resistant Staphylococcus aureus (MRSA) was identified. The SlipChip will be useful for applications involving PCR arrays and lays the foundation for new strategies for diagnostics, point-of-care devices, and immobilization-based arrays.

Additional Information

© 2010 American Chemical Society. Published In Issue: June 01, 2010. Article ASAP: May 06, 2010. Received: March 19, 2010. Accepted: April 14, 2010. This work was supported by the NIH Director's Pioneer Award program, part of the NIH Roadmap for Medical Research (1 DP1 OD003584). Part of this work was performed at the Materials Research Science and Engineering Centers microfluidic facility (funded by the National Science Foundation). We thank Heidi Park for contributions to writing and editing this manuscript.

Attached Files

Accepted Version - nihms203006.pdf

Supplemental Material - Ismagilov_Anal_Chem_2010_multiplex_PCR_slipchip_FS_WD_ED_MK_JP_supp_info.pdf

Files

nihms203006.pdf
Files (1.7 MB)
Name Size Download all
md5:baec5d705582c611911e678617ff6159
1.6 MB Preview Download
md5:eee054613dea2c5279b4dcb8ed1e352f
90.0 kB Preview Download

Additional details

Created:
August 19, 2023
Modified:
October 24, 2023